If your GreenCity 2 sprayer does not gain pressure, it probably has a leak. One of the sealing parts may be dirty, damaged or incorrectly positioned. To identify the problem and fix it, follow the steps below:
DO YOU SEE MARKS ON THE FILLER NOZZLE OF THE CONTAINER?
Check it visually and by touch. If there are any, replace the container; if not, continue with the second step.
FLAP VALVE
Remove the container and make sure that the flap valve is in good condition. If it is dirty, clean it and put it back in place. If it is damaged or has a mark/damage, replace it with a new one: Evo 2 Maintenance Kit.
CHAMBER
Make sure that the chamber, screwed to the sprayer head, is properly tightened and that the gasket is in good condition. If the gasket is damaged, replace it.
STEM SEAL
Remove the plunger from the sprayer head and ensure that the stem seal is correctly fitted or if it is damaged. Make sure it is correctly positioned, and replace it if damaged.
CONTAINER SEAL
Lastly, check that the container seal is clean and well-positioned. If it is damaged and/or has a mark/damage, replace it with a new one.
If your GreenCity 7 sprayer does not gain pressure, it probably has a leak. One of the sealing parts may be dirty, damaged or incorrectly positioned. To identify the problem and fix it, follow the steps below:
DO YOU SEE MARKS ON THE FILLER NOZZLE OF THE CONTAINER?
Check it visually and by touch. If there are any, replace the container; if not, continue with the second step.
STEM RETAINER
Remove the stem (1) Remove the container cap (2) Lift the plunger and remove the clips (3) Insert your hand into the container through the filler nozzle and rotate the chamber to release it (4) Once the chamber is released, remove the plunger from the top and check if the stem retainer is correctly positioned and in good condition. If it is damaged, replace it with a new one. Evo 7 Maintenance Kit.
FLAP VALVE
Check that the flap valve of the chamber is correctly positioned and free of dirt and marks. If it is broken or damaged, replace it with a new one: Evo 7 Maintenance Kit.
CHAMBER
Make sure that the chamber seal is in good condition. If not, replace it with a new one: Evo 7 Maintenance Kit.
CAP
Lastly, make sure that the seal on the container cap is in place and good condition; otherwise, replace it.
Deze site maakt gebruik van cookies, zodat wij je de best mogelijke gebruikerservaring kunnen bieden. Cookie-informatie wordt opgeslagen in je browser en voert functies uit zoals het herkennen wanneer je terugkeert naar onze site en helpt ons team om te begrijpen welke delen van de site je het meest interessant en nuttig vindt.